- Better triaging tools for Acute Coronary Syndrome (ACS) detection
- Configurable Crtical Values to help speed time to treatment
- More accurate pacemaker detection for advanced interpretation of paced rhythms (part of the high definition cam acquisition module, HD)
- Enhanced barcode workflow, with orders and ADT download capability, work together to help improve efficiency across the enterprise
- Connected ECG Workflow to help save time and avoid costly misdiagnoses
Display
Display Type – 10.4 in (264 mm) diagonal graphics backlit color AM LCD
Display Resolution – 640 x 480 pixels with waveform enhancement
Display Data – Heart rate, patient name, ID, clock, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts, and help messages
Writer
Writer Technology – Thermal dot array
Writer Speeds – 5, 12.5, 25, and 50 mm/s
Number of Traces – 3, 6, 12, or 15 user selectable
Writer Sensitivity/Gain – 2.5, 5, 10, 20, 10/5 (split calibration) mm/mV
Writer Speed Accuracy – ±2% Writer
Amplitude Accuracy – ±5%
Writer Resolution – Horizontal 1000 dpi @ 25 mm/s, 200 dpi vertical
Paper Type – Thermal, Z-fold, perforated, fan fold, 300 sheets/pack
Paper Size A Size – 8.5 in x 11 in, (214.6 mm x 280 mm) A4 Size: 8.27 in x 11.7 in (210 mm x 297.5 mm)
Keyboard
Type – Sealed elastomer with soft function keys, alphanumeric keys, writer controls, and TrimPad cursor controls
Electrical
Power Supply – AC or battery operation
Voltage – 100 to 240 VAC
Current – 0.5A @ 115 VAC, 0.3A @ 240 VAC, typical, 0.85A max
Frequency – 50 to 60 Hz
Battery Type – User replaceable, 18V @ 3.5 AH ±10% rechargeable NiMH
Battery Capacity – 100 single page reports, (typical) or six hours continuous display (without printing)
Battery Charge Time – Approximately 4.5 hours from total discharge (with display off)
Vectorcardiography
Report Formats – Vector loops of component vectors (P, QRS, ST-T)
Sensitivity – 20, 40, 80, or 160 mm/mV
Time Resolution – 2 ms
Hi-Res Late Potential Analysis and P-Wave Signal– Averaged ECG
Sensitivities:
Raw Data Template – 20 mm/mV
Average Beat – 20 mm/mV and 50 mm/mV
Filtered Signals and Vector Magnitude – 1 mm/µV
Analysis Sampling Rate – 1,000 samples/second/channel
Digital Sampling Rate – 16,000 samples/second/channel
High/Low Pass Filters Special filter using Fast Fourier Transform (FFT)
Physical Specifications
Height – 3.7 in (9.4 cm)† with display closed
Width – 15 in (38.1 cm)†
Depth – 13.8 in (35.1 cm)†
Weight – Approximately 6.8 kg (15 lbs)† including battery, without paper
Environmental Specifications
Temperature
Operating – 50°to 104° F (10° to 40° C)
Transport/Storage – –40°to 158° F (–40° to 70° C)
Humidity
Operating – 20% to 95% RH non-condensing
Transport/Storage – 15% to 95% RH non-condensing
Pressure
Operating – 700 to 1060 hPA
Transport/Storage – 500 to 1060 hPA
Magnetic Card Reader Specifications
Character Set ANSI/ISO ALPHA alphanumeric characters and ANSI/ISO BCD (subset of ASCII [ISO 646 IRV:1991])
Bar Code Scanner Specifications
Symbologies Code 39 (extended), PDF-417, Code 128, Data Matrix, Interleaved 2 of 5
Modular MAC Trolley Dimensions
Height – 37 in (94 cm)
Width – 19 in (47 cm)
Depth – 27 in (69 cm)
Height with Acquisition module holder – 59 in (150 cm)
Weight – 66 lbs. (30 kg)††
Options – Barcode scanner holder
Valoraciones