The ERBE ICC 300 is a high-frequency surgical unit for cutting and coagulation. It’s the price-conscious solution for medium and major surgical procedures. After all, a smooth routine in the operating room depends on maximum safety, a high degree of comfort in use, and perfect functionality – exactly the features of the ICC 300 . And it also meets the special demands of Minimally Invasive Surgery.  
  • CUT CONTROL for automatically perfect cuts. Reproducible cut quality with minimum necrosis
  • HlGH CUT with specialized arc regulation for underwater cuts or in fatty structures
  • SOFT coagulation for precisely controlled coagulation
  • No carbonization (SOFT COAG)
  • Far less adhesion and electrode soiling
  • Bipolar coagulation for even greater safety
  • PPS for intelligent support of initial incisions and cutting
  • AUTO START for the greater facility of bipolar coagulation
  • SPRAY coagulation for better surface effects
  • ARGONPLASIVIA coagulation via an integrated plug-in connection

Dimensions

  • Dimensions (HxWxD) cm, (In) (Display) 41 x 15.2 x 36.8 (16.1 x 5.9 x 14.5)
  • Weights, kg (lb) (Display) 10 (22)

Electrical

  • Monopolar (Systems) Cut(blend), coagulate
  • Max. energy output ( at rated ohms) (SYSTEMS) More than 250 Watt 300
  • Max voltage, vp-p (Systems) 1200
  • Max. energy output ( at rated ohms) (SYSTEMS) Up to 150 Watt 120
  • Max voltage, vp-p (Systems) 380 soft, 5,600 spray
  • Bipolar (SYSTEMS) Coagulate
  • Max. energy output ( at rated ohms) (SYSTEMS) Up to 150 Watt 120
  • Max voltage, vp-p (Systems) 380

Power Connection

  • Rated power voltage 240 V / 230 V / 115 V / 110 V / 100 V ± 10 %
  • Rated power frequency 50 / 60 Hz
  • Power current 4.0 A at 230 – 240 V / 8.0 A at 100 – 115 V
  • Power consumption in Standby mode 25 watts <?li>
  • Power consumption at max. HF power 620 watts 920 VA
  • Current consumption in Standby mode 150 mA at 230 – 240 V / 300 mA at 100 – 115 V
  • Potential equalization terminal yes
  • Power fuses 2 slow burn, 4 A at 230 – 240 V / 8 A at 100 – 115 V

Environmental Conditions for Storage

  • Temperature -40°C to + 70°C
  • Air humidity, relative 30% to 95%

Environmental Conditions for Operating

  • Temperature +10°C to + 40°C
  • Air humidity, relative 30% to 75%, non-condensing

Cutting, monopolar with automatic voltage control (Auto Cut)

  • HF voltage waveform unmodulated sinusoidal alternating voltage
  • Crest factor C, at RL = 500 ohms C = 1.4 for all settings
  • Rated frequency 330 kHz
  • Maximum HF voltage at load resistance RL = 8 650 VP
  • Dynamic internal impedance in rated load range 0 ohm
  • The constancy of the HF voltage at RL> 350 ohms automatically controlled
  • Cutting quality 4 coagulation effects selectable by key
  • The constancy of the 4 coagulation effects automatically controlled
  • HF rated power 300 watts at RL = 500 ohms
  • HF power limitation 1 to 300 watts in 1 watt steps
  • Setting of the HF power limitation via up/down keys
  • Display of the HF power limitation 7-segment display, 3 decimal places
  • Precision of the HF power limitation +/- 1 digit or +/- 15%
  • Activation of Cutting mode by key or pedal
  • HF connecting sockets 2, electronically locked from one another

Cutting, monopoly with automatic arc control (High Cut)

  • HF voltage waveform unmodulated sinusoidal alternating voltage
  • Crest factor C, at RL = 500 ohms C = 1.4 for all settings
  • The rated frequency of the HF voltage is 330 kHz
  • Maximum HF voltage at load resistance RL = 8 570 VP
  • The constancy of the intensity of the electric arc automatically controlled
  • Cutting quality 4 coagulation effects selectable by key
  • The constancy of the 4 coagulation effects automatically controlled
  • HF rated power 300 watts at RL = 500 ohms
  • HF power limitation 1 to 300 watts in 1 watt steps Setting of the
  • HF power limitation via up/down keys Display of the
  • HF power limitation 7-segment display, 3 decimal places
  • Precision of the HF power limitation +/- 1 digit or +/- 15%
  • PPS (Power Peak System) yes
  • Activation of Cutting mode by key or pedal
  • HF connecting sockets 2, electronically locked from one another

Soft Coagulation (Soft Coag)

  • HF voltage waveform unmodulated sinusoidal alternating voltage
  • Crest factor C, at RL = 500 ohms C = 1.4 for all settings
  • The rated frequency of the HF voltage is 330 kHz
  • The peak value of the HF voltage max. 1900 VP
  • The constancy of the HF voltage automatically controlled
  • HF-rated power 120 watts at 125 ohms
  • HF power limitation (PHFmax.) from 1 watt to 120 watts in 1 watt steps
  • Setting of the HF power limitation via up/down keys
  • Display of the HF power limitation 7-segment display, 3 decimal places
  • Precision of the HF power limitation +/- 1 digit or +/- 15%
  • Activation of Cutting mode by key or pedal
  • HF connecting sockets 2, electronically locked from one another

 

0 reviews
0
0
0
0
0

There are no reviews yet.